Search This Blog

Thursday, November 15, 2012

Stacking PowerConnect 6248p Switches When They Both Come Up as Master

We received two new Dell PowerConnect 6248p switches from Dell this week.  In installed two 10gbe stacking units with the switches and cross connected them.  I was surprised when I powered them up (the one I hooked my console cable into was booted first) that they both came up as masters and they went into a strange loop of booting operational mode over and over.

I shut them down and booted up just the one switch.  It was in the loop still and so I went ahead and reset it to the factory settings.  Upon reboot it presented me with the wizard option to setup the switch and allowed me to go through the config.  I did a factory reset on the other switch as well but they still would not stack.

To get them to stack I had to perform the following on both switches, then reboot them both.

If you've not configured switches before everything after the # is what you type for the command so only type what is in bold below

en (enables the console)
console#show stack-port
console#config
console(config)#stack
console(config-stack)#stack-port 1/xg1 stack
console(config-stack)#stack-port 1/xg2 stack
console(config-stack)#exit
console(config)#exit
console#copy run start

I then rebooted both switches and the one I rebooted first came up as the master.  This probably took it about a 5 minute cycle to configure them and reboot them both.  Now they are a stacked switch.

If you go back to your console again (hooked up to the switch with the Master led lit up you can again go to show stack-port and it should now show them as Stack instead of Ethernet and Link Up as the status.

No comments: